真空吸塵器耐壓測試規範(doc 6頁)
真空吸塵器耐壓測試規範(doc 6頁)內容簡介
真空吸塵器耐壓測試規範內容提要:
1.0 Purpose / 目的
To evaluate the performance of dielectric voltage-withstand of the sample
評估樣機絕緣材料的絕緣耐壓性能.
2.0 Definition/概念:
None 無.
3.0 Reference Documents/參考文獻:
U.L.1017 CAN/CSA-C22.2 NO.243-01, dated 12-7-2001,CL 5.11
4.0 Equipment/設備:
Withstanding voltage tester(耐壓測試儀).
5.0 General Instructions/說明:
5.1 Tests may be conducted at any ambient temperature within a range of 10-40℃ (50-100℉).
測試可在10~40℃(50~100℉)之內的環境溫度下進行.
5.2 Unless otherwise noted, all tests are to be conducted with appliance connected to a 120VAC, 60Hz power source.
除非另外標注, 否則所有樣板都將連接在120V/60Hz電源下進行測試.
5.3 All equipment used must be calibrated on an annual basis. Calibration stickers with last calibration and calibration due date must be affixed to each instrument.
使用的所有設備都必須以一年為周期進行調校.載有最後調校日期和調校周期的調校粘紙必須粘固在每一個儀表上.
..............................
1.0 Purpose / 目的
To evaluate the performance of dielectric voltage-withstand of the sample
評估樣機絕緣材料的絕緣耐壓性能.
2.0 Definition/概念:
None 無.
3.0 Reference Documents/參考文獻:
U.L.1017 CAN/CSA-C22.2 NO.243-01, dated 12-7-2001,CL 5.11
4.0 Equipment/設備:
Withstanding voltage tester(耐壓測試儀).
5.0 General Instructions/說明:
5.1 Tests may be conducted at any ambient temperature within a range of 10-40℃ (50-100℉).
測試可在10~40℃(50~100℉)之內的環境溫度下進行.
5.2 Unless otherwise noted, all tests are to be conducted with appliance connected to a 120VAC, 60Hz power source.
除非另外標注, 否則所有樣板都將連接在120V/60Hz電源下進行測試.
5.3 All equipment used must be calibrated on an annual basis. Calibration stickers with last calibration and calibration due date must be affixed to each instrument.
使用的所有設備都必須以一年為周期進行調校.載有最後調校日期和調校周期的調校粘紙必須粘固在每一個儀表上.
..............................